BibTex RIS Kaynak Göster

Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis

Yıl 2009, Cilt: 22 Sayı: 3, 149 - 155, 26.03.2010

Öz

System suitability test (SST) is a test to determine the suitability and effectiveness of chromatographic system prior to use. The performance of any chromatographic system may continuously change during their regular use, which can affect the reliability of the analytical results. The operation parameters of the whole chromatographic system can be checked with properly selected SST mixtures. These mixtures are used to establish characteristic chromatographic parameters, such as the number of effective theoretical plates, resolution, asymmetry, detection limit and selectivity. The system is then only declared suitable if the responses are within given limits. This study was performed to set system suitability criteria for detectability in gas chromatography-nitrogen phosphorus detection (GC-NPD) methods for pesticide residue analysis. Under our laboratory and analysis conditions, asymmetry and tailing of dimethoate and tributylphosphate (TBP) peaks slightly changed after 63 standard and/or sample injections; however these changes were within the required limits.

 

Key Words: System Suitability Test (SST), GC Performance, GC Optimization.

 

Yıl 2009, Cilt: 22 Sayı: 3, 149 - 155, 26.03.2010

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Chemistry
Yazarlar

Osman Tiryaki

Dilan Baysoyu Bu kişi benim

Gülizar Aydın Bu kişi benim

Emine Seçer Bu kişi benim

Yayımlanma Tarihi 26 Mart 2010
Yayımlandığı Sayı Yıl 2009 Cilt: 22 Sayı: 3

Kaynak Göster

APA Tiryaki, O., Baysoyu, D., Aydın, G., Seçer, E. (2010). Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis. Gazi University Journal of Science, 22(3), 149-155.
AMA Tiryaki O, Baysoyu D, Aydın G, Seçer E. Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis. Gazi University Journal of Science. Mart 2010;22(3):149-155.
Chicago Tiryaki, Osman, Dilan Baysoyu, Gülizar Aydın, ve Emine Seçer. “Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis”. Gazi University Journal of Science 22, sy. 3 (Mart 2010): 149-55.
EndNote Tiryaki O, Baysoyu D, Aydın G, Seçer E (01 Mart 2010) Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis. Gazi University Journal of Science 22 3 149–155.
IEEE O. Tiryaki, D. Baysoyu, G. Aydın, ve E. Seçer, “Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis”, Gazi University Journal of Science, c. 22, sy. 3, ss. 149–155, 2010.
ISNAD Tiryaki, Osman vd. “Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis”. Gazi University Journal of Science 22/3 (Mart 2010), 149-155.
JAMA Tiryaki O, Baysoyu D, Aydın G, Seçer E. Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis. Gazi University Journal of Science. 2010;22:149–155.
MLA Tiryaki, Osman vd. “Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis”. Gazi University Journal of Science, c. 22, sy. 3, 2010, ss. 149-55.
Vancouver Tiryaki O, Baysoyu D, Aydın G, Seçer E. Setting System Suitability Parameters for Performance Optimization of GC-NPD Detection for Pesticide Residue Analysis. Gazi University Journal of Science. 2010;22(3):149-55.