This study aimed to compare the corrosion cast models of the porcine head arterial system with three-dimensional (3D) reconstructions using cone beam computed tomography (CBCT) of these cast models. Six heads from sows were simultaneously injected through both carotid arteries with Duracryl Plus for corrosion cast technique and an additional head, also from another one sow head, was filled with saturated lead tetroxide (Pb3O4) in a 10% hot water solution (40°C) of gelatin for CBCT study. Two-dimensional (2D) images were stored in Digital Imaging and Communications in Medicine (DICOM). Subsequently, segmentation and post-processing of these images were performed by using various software programs. The 3D models were found to be compatible with the corrosion cast models. It was observed that osseous structures and arteries were clearly identified on CBCT images. Specimen scan, segmentation, and post segmentation had a duration of 10-15 minutes, 4 hours, and 15 minutes, respectively. The internal carotid artery, external carotid artery, and its main branches were seen well on 3D models. In conclusion, it is considered that 3D models and images can be effectively used in anatomy education, radiological evaluations, pathological and variational investigations.
artery, cone beam computed tomography, corrosion cast, pig, three dimensional reconstruction
Birincil Dil | İngilizce |
---|---|
Konular | Veteriner Hekimlik |
Bölüm | Araştırma Makalesi |
Yazarlar |
|
Yayımlanma Tarihi | 30 Eylül 2022 |
Yayınlandığı Sayı | Yıl 2022Cilt: 69 Sayı: 4 |
Bibtex | @araştırma makalesi { auvfd884974, journal = {Ankara Üniversitesi Veteriner Fakültesi Dergisi}, issn = {1300-0861}, eissn = {1308-2817}, address = {}, publisher = {Ankara Üniversitesi}, year = {2022}, volume = {69}, number = {4}, pages = {419 - 424}, doi = {10.33988/auvfd.884974}, title = {Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography}, key = {cite}, author = {Tsandev, Nikolay and Bakıcı, Caner and Vodenicharov, Angel} } |
APA | Tsandev, N. , Bakıcı, C. & Vodenicharov, A. (2022). Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography . Ankara Üniversitesi Veteriner Fakültesi Dergisi , 69 (4) , 419-424 . DOI: 10.33988/auvfd.884974 |
MLA | Tsandev, N. , Bakıcı, C. , Vodenicharov, A. "Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography" . Ankara Üniversitesi Veteriner Fakültesi Dergisi 69 (2022 ): 419-424 <http://vetjournal.ankara.edu.tr/tr/pub/issue/72819/884974> |
Chicago | Tsandev, N. , Bakıcı, C. , Vodenicharov, A. "Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography". Ankara Üniversitesi Veteriner Fakültesi Dergisi 69 (2022 ): 419-424 |
RIS | TY - JOUR T1 - Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography AU - NikolayTsandev, CanerBakıcı, AngelVodenicharov Y1 - 2022 PY - 2022 N1 - doi: 10.33988/auvfd.884974 DO - 10.33988/auvfd.884974 T2 - Ankara Üniversitesi Veteriner Fakültesi Dergisi JF - Journal JO - JOR SP - 419 EP - 424 VL - 69 IS - 4 SN - 1300-0861-1308-2817 M3 - doi: 10.33988/auvfd.884974 UR - https://doi.org/10.33988/auvfd.884974 Y2 - 2021 ER - |
EndNote | %0 Ankara Üniversitesi Veteriner Fakültesi Dergisi Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography %A Nikolay Tsandev , Caner Bakıcı , Angel Vodenicharov %T Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography %D 2022 %J Ankara Üniversitesi Veteriner Fakültesi Dergisi %P 1300-0861-1308-2817 %V 69 %N 4 %R doi: 10.33988/auvfd.884974 %U 10.33988/auvfd.884974 |
ISNAD | Tsandev, Nikolay , Bakıcı, Caner , Vodenicharov, Angel . "Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography". Ankara Üniversitesi Veteriner Fakültesi Dergisi 69 / 4 (Eylül 2022): 419-424 . https://doi.org/10.33988/auvfd.884974 |
AMA | Tsandev N. , Bakıcı C. , Vodenicharov A. Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography. Ankara Univ Vet Fak Derg. 2022; 69(4): 419-424. |
Vancouver | Tsandev N. , Bakıcı C. , Vodenicharov A. Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography. Ankara Üniversitesi Veteriner Fakültesi Dergisi. 2022; 69(4): 419-424. |
IEEE | N. Tsandev , C. Bakıcı ve A. Vodenicharov , "Evaluation of the compatibility between corrosion casts and 3D reconstruction of pig head arterial system on cone beam computed tomography", Ankara Üniversitesi Veteriner Fakültesi Dergisi, c. 69, sayı. 4, ss. 419-424, Eyl. 2022, doi:10.33988/auvfd.884974 |